PMC Generation General - Intergraph Smart Materials - Version 10.1 - Administration & Configuration - Hexagon

Intergraph Smart Materials Integration (10.1)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Administration & Configuration
Smart Construction Version
8
Smart Materials/Smart Reference Data Version
10.1

With each generation of a spec on PDS 10.12, you create entries for the PMC file in a Smart Materials table. The created entries can be viewed as well as edited manually on PDS 10.12/13/14. The ASCII generation of the PMC file is performed on the PDS 10.14 View PMCs and generate ASCII screen.

The ASCII file will contain the list of available PMC information for each spec in the product group/project. There are four check boxes to control the scope of the output (See picture above). You can choose to print only specs of the highest revision, only those that are issued, only those specs within the logged in project/product group, or only those of the selected spec type. You can combine these criteria. For example, you may want to output all issued specs, but only those with the highest revision and just for this spec type. If you decided to save old PMCs of the same spec by selecting Do NOT delete old data on PDS 10.12, the latest PMC is being taken.

The PMC-Specials tab on PDS 10.01 allows you to configure the layout of the items.