Rating - Intergraph Smart Materials - Version 10.1 - Administration & Configuration - Hexagon

Intergraph Smart Materials Integration (10.1)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Administration & Configuration
Smart Construction Version
8
Smart Materials/Smart Reference Data Version
10.1

Like the end preparation, the interface offers two different methods for selecting the rating of a component, but these methods cannot be selected in all cases. The rating is contained in the commodity code. If the software does not find the rating within the commodity code, the S.20.08 method is automatically used.

The map name for the Smart Materials table on A.50.I.01 must be RATING for the green connect point, or ARATING for the red connect point. You can have more than one table for this purpose. Map additional tables by appending a sequential number to the mapname like <mapname>_1, and so forth on A.50.I.01. If the commodity code contains a link table, the PDS interface will also be able to find information in the linked table as long as the translation on A.50.I.01 is made.

In the Source field, you must enter the attribute of the mapped Smart Materials table in which the PDS rating value can be found for the green and the red connect point.

The following possibilities exist:

  • Table Detail - value in TD Code is taken

  • S.20.I.01 - translated value from S.20.I.01 is taken

  • ATTR_CHAR1 - value of ATTR_CHAR1 is taken

  • ATTR_CHAR2 - value of ATTR_CHAR2 is taken

  • ATTR_CHAR3 - value of ATTR_CHAR3 is taken

  • ATTR_NUM1 - value of ATTR_NUM1 is taken

  • ATTR_NUM2 - value of ATTR_NUM2 is taken

  • ATTR_NUM3 - value of ATTR_NUM3 is taken

The PCD ratings begin with the prefix CL if ANSI applies, for example, CL300. The name for the PDS geometry is only 300, however. If DIN applies, the class must be followed by a "#".

We suggest that users enter the tables for the ratings without the CL or "#" and append the CL or "#" in the PCD via procedure.