If all data are correct and the update has been done successfully, a blank (‘ ‘) will be returned in parameter result.

Otherwise, result contains all errors that were found for the given data. In most cases, a numeric error message is completed by the name of the faulty column.

Example:

If m_api_pll_dns.upd_dn has been called, a value that looks like this can be returned:

Result = 201,104 – UNIT_WT_ID,102 – PLL_COMMENT,101 –

UNIT_DT_ID,106 – UNIT_WT_ID,HEADER

This means in detail:

  • The given DN does not exist (201).

  • The value for UNIT_WT_ID is not a numeric one (104).

  • The value for PLL_COMMENT is too large (102).

  • UNIT_DT_ID cannot be set to NULL (101).

  • The value for UNIT_WT_ID is not valid, perhaps a unit not belonging to Smart Materials units (106).

  • A column named HEADER is not supported by this package.