Impact of the settings in Smart Materials Portal

The COMP_REG_QLF DBA setting must be specified to run the Portal.

With this DBA setting, you can define the required approval steps for the company registration. The valid values are 1-Step, 2-Step, 2-Step (alt.), and 3-Step.

  • If COMP_REG_QLF is set to 1-Step and the data is entered and submitted, the new registered company is approved.

    All data needed for the company registration can be entered in the Portal before the registration is submitted and approved.

  • If COMP_REG_QLF is set to 2-Step, an additional approval step is defined. The registering company submits the company and user information, the company profile, and the materials and services information in the first step. The submitted data must be approved before the company can continue with the qualifications questionnaire.

  • If COMP_REG_QLF is set to 2-Step (alt.), the company profile must be approved before the Material and Services tab is enabled. This means, the registering company must submit the company and user information, and the company profile in the first step. The submitted data must be approved before the company can continue with the materials and services information and the qualifications questionnaire.

    If COMP_REG_QLF is set to 3-Step, a third approval step is defined. In addition to the 2-Step approval, the registering company must submit the company and user information. The company can continue with the registration only if the submitted data is approved.

Display setting for P.20.03 if called via E-Supplier Login

In P.20.03 Questionnaire, this setting affects the visibility of top-level nodes in the questionnaire tree if the screen has been called from the E-Supplier Login (this is not applicable if the screen is called from the menu in Smart Materials).

The 1-Step value will not restrict the number of top-level nodes displayed in the tree at all; that is, the company that has opened the screen via E-Supplier Login will be able to answer questions below all three top-level nodes from the very beginning.

The 2-Step and 3-Step values will cause P.20.03 to show the Login Details and Company Profile top-level nodes only. After a company has submitted its answers to all the (mandatory) questions below those top-level nodes, and after these answers (also known as company profile) have been approved, a new call of P.20.03 by the company (via E-Supplier Login) will yield the complete questionnaire tree.

The difference between the 2-Step and 3-Step values will become evident on P.20.02 Login Requests only; that is, when set to 3-Step, the submitted login request must be approved via approval sequence before answers for the company profile and/or qualifications can be entered on P.20.03 Questionnaire via Supplier Entry.

  • Module(s) affected by this setting: Portal, A2049, P2002, P2003

  • Valid values: 1-Step, 2-Step, 3-Step. Additionally, only for the Portal: 2-Step (alt.)