4. Configure mapping - Intergraph Smart Interop Publisher - Help

Intergraph Smart Interop Publisher Help

Language
English
Product
Intergraph Smart Interop Publisher
Search by Category
Help
Smart Interop Publisher Version
16.2

Follow the steps below to use the AutoPLANT custom mapping file to map the VOLUME property to the Hexagon Asset Lifecycle Intelligence PipingFluidVolume property under the IJR3DPipingItem interface.

This property is already mapped in SmartPlant Foundation. You do not have to do additional steps on mapping into SmartPlant Foundation using SPF 2016. To check on all property mapping available for SmartPlant Foundation, you can look at the SPFMapping sheet in the SPIOPschema.xlsx file delivered by default in the [drive]:\Program Files\SmartPlant\Interop Publisher folder.

  1. Copy the custom mapping template file to a different folder location. For your convenience, Smart Interop Publisher automatically creates a \3DInteropMappingFiles\CustomMappingFiles subfolder under your defined shared content location in which you can copy the file.

  2. From the PropertyMap sheet in the CustomAutoPLANTToR3DMapping.xls file, locate the AT_PIPE Source Class and create a new row with the following information:

    • Source Property - VOLUME

    • Target Interface - IJR3DPipingItem

    • Target Property - PipingFluidVolume

      SmartPlant Foundation displays the Target Property value in the translated model. This value does not have to be the same name as the Source Property value.

  3. In the Units column G , enter mm^3 to set the units of measure value to display millimeters.

    When entering the units of measure for models being translated and published to SmartPlant Foundation, you must type in the format as specified in SmartPlant Foundation. See Units of Measure Entries.

  4. Save your edits. Save the edited mapping spreadsheet file in the Microsoft Excel 97-2003 Workbook (.xls) format.