Create a Format for a Multi-Tag Spec - Intergraph Smart Instrumentation - Training - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Tutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
2018 (12.0)
  1. In the Specifications Module window, on the toolbar, click Format Editor icon 16bit (Formats).

  2. In the Format Editor, on the toolbar, click Open Format icon 16bit (Open Format).

  3. On the Select Specification Form dialog box, select form number 8 and click OK.

  4. On the Select Format dialog box, type a format name as shown.

  5. Click OK to open the Format Editor with the Edit Headers pop-up window on top of it.

    • Smart Instrumentation displays the field headers on the left side of the Format Editor, and the field selections on the right side of the window.

    • Field headers that you add in the Edit Headers pop-up window appear on the SEE LIST page after you generate a multi-tag spec. In the pop-up window, you can modify the sequence of the header names and define the header sequence for the SEE LIST page.

  6. Drag the Edit Headers pop-up window out of the way so that you can see most of the Format Editor window

  7. Add the following fields to the Edit Headers pop-up window (the Tag Number appears in the pop-up window by default):

    1. In the Format Editor window, move the cursor over the cmpnt_serv (Service) field and note that the cursor changes its shape to .

    2. Double-click in the field selection of the Service field.

    3. In the Edit Headers pop-up window, under Column Header, the text General Service appears. Edit this text to read Service.

    4. Point the cursor to line #13 and double-click in the leftmost field selection, calib_range_min. The field changes its color and appears in the Edit Headers pop-up window under Column Header.

    5. In the Edit Headers pop-up window, change the label from calib_range_min to Minimum Range.

    6. Again in line #13, double-click the second field from the left, calib_range_uom_min, and in the Edit Headers pop-up window, change the label to Range UOM.

    7. Double-click the fourth field from the left, calib_range_max, and in the Edit Headers pop-up window, change the label to Maximum Range. Click Move Up to place above Range UOM.

    8. The headers in the pop-up window should appear as shown. If you make a mistake, you can cancel the field assignment by selecting the selection in the Edit Headers pop-up window and clicking Remove.

  8. On the menu bar, click Actions > Generate Format.

  9. On the Generate Format dialog box, drag the Range UOM header to the extreme right and modify the header widths by dragging the border between headers to the right or to the left so that the headers appear as shown.

  10. Save the format.

  11. When done, on the main toolbar, click Close icon 16bit (Close).

You have now successfully created your multi-tag (see-list) spec format, which you can now use for your pressure gauges.