Now you will learn how to automate entry of common data to your specification by using a form data template that you created for the form upon which the flow transmitter spec is based.
-
On the Specifications Module window module toolbar, click (Open Spec).
-
On the Open Specification dialog box, do the following:
-
Under Item type, select Instrument.
-
Under Item number, type 101-FT-100.
-
Under Form number, type 56.
-
Click OK to open the Instrument Specification window for flow transmitter 101-FT-100.
The specification was generated when you created the 101-FT-100 tag, according to the instrument type profile settings.
-
-
In the Select Fluid State pop-up window, select Liquid and click OK.
-
On the Actions menu, click Copy from Template.
-
On the Select Form Data Template dialog box, select the new form data template that you created, D/P XMTR TYPE 1.
-
Click OK to copy data from the form data template to the specification sheet.
The values in the protected fields are not overwritten.
-
Save and close the specification.