In this procedure, you use the Domain Explorer to open a process data sheet for instrument tag 101-FV-100. Then, you copy process data from flowmeter
101-FE-100 and modify the values for the control valve.
-
Press F7 to open the Domain Explorer.
-
Expand the hierarchy New Refinery > Crude Area > Crude Unit 1 > Instruments.
-
Right click 101-FV-100.
-
On the shortcut menu, click Actions > Generate a Process Data Sheet.
-
On the Results dialog box, check whether the Result Description column indicates that the process data sheet has been generated successfully, and then, click OK.
-
On the Domain Explorer toolbar, click (Refresh).
Process data document 101-FV-100-PD should now appear under 101-FV-100, in addition to spec document 101-FV-100-SP, which was created automatically according to the instrument type profile definitions:
-
Right-click 101-FV-100-PD.
-
On the shortcut menu, click Actions > Open Document to open the Control Valve Process Data window.
-
Close the Domain Explorer to maximize the Control Valve Process Data window.
-
On the menu bar, click Edit > Copy From > Instrument.
-
On the Copy From Instrument dialog box, type 101-FE-100, and then, click OK.
-
In the Properties section, define the pressure drop and upstream pressure values and ensure that the other values appear as shown.
-
Scroll down to display the Additional Properties section, and specify the following control valve properties.
-
Generate a control valve process data report. On the module toolbar, click (Save). Then add a revision as you have previously done for the flow-meter process data report.