Generate a Specification for a Flowmeter - Intergraph Smart Instrumentation - 13.1 - Training - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Tutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
13.1

In this procedure, you use the Specifications module options to generate an instrument specification for the tag
101-FE-100 and define orifice flange properties.

  1. To open the Specifications module, do one of the following

    • On the main toolbar, click Specifications icon 16bit.

    • On the Modules menu, click Specifications.

  2. On the Specifications Module window toolbar, click Open Spec icon 16bit (Open Spec).

  3. On the Open Specification dialog box, place the cursor in the Item number box, and then click Find.

  4. On the Open Specification - Find Items dialog box, select 101-FE-100, and then click OK.

    The information in the Open Specification - Find Items displayed as shown:

  5. On the Open Specification dialog box, place the cursor in the Form number box.

  6. Type 11 as the Form Number, and then click Find.

  7. On the Select Specification - Find Items dialog box, select from 11 Orifice Plate, and then click OK.

  8. On the module toolbar, click Save Icon 16bit to save the specification sheet. Compare to the Specification Sheet below.

    This spec sheet already contains data (Service, Line Number, process conditions, and so forth) that was already entered or calculated in the previous tasks. It is optional to add information to the Orifice Flanges and Purchase sections.

  9. On the module toolbar, click PPM All Outputs Graphic to refresh the specification sheet.

  10. Click the Page 1 tab and view the note that you typed in the Notes section of the specification sheet.

  11. Click to close this specification sheet and return the Specifications Module window.