Define a Loop and Add Tag Numbers - Intergraph Smart Instrumentation - 13.1 - Training - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Tutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
13.1
  1. Click Tools > Domain Explorer.

  2. Under Domain Explorer, expand the plant hierarchy as follows: New Refinery > Crude Area > Crude Unit 1.

  3. Under Crude Unit 1, right-click the Loops folder, and on the shortcut menu, click New > Loop.

  4. On the New Loop Number dialog box, type the loop number: 101-F -100.

    • Use the Tab key to move the cursor to the character separators.

    • The first segment of the loop number is derived from the unit number as you defined it in the loop naming convention and cannot be edited.

  5. Click OK.

  6. On the Loop Number Properties dialog box, type the following information:

    1. In the Loop service box, type Feed from V8.

    2. From the Loop type list, select DCS.

    3. From the P&ID drawing list, select 101-PID01-001.

    4. Clear the Apply equipment to tags check box.

      The dialog box should appear as shown:

      SHARED Tip To add new values to supporting tables so that they can become available in the lists, click next to the lists.

  7. Click OK.

  8. Click Yes when prompted to create a tag numbers.

  9. On the New Tag Number dialog box, type FE as the first new tag number.

  10. Click OK.

  11. On the Select Instrument Type dialog box, select the D/P Type Flow Element description for instrument type FE as shown.

    SHARED Tip You need to select an instrument type because more than one instrument type designated by the FE acronym exists.

  12. Click OK to open the Tag Number Properties dialog box.

  13. Type tag number data by selecting values from the lists as shown.

    SHARED Tip The ellipsis buttons enable you to enter additional data in the supporting data tables. These values then become available in the select lists.

  14. Click Apply when done.

  15. Click New to add another tag number to the loop as follows:

    1. On the New Tag Number dialog box, type FT so that the tag number is 101-FT-100 and click OK.

    2. On the Select Instrument Type dialog box, select the D/P Type Flow Transmitter description for instrument type FT.

      SHARED Tip While the software is creating this tag number, the status bar indicates automatic device panel creation.

    3. On the Tag Number Properties dialog box, complete the definitions as shown.

  16. Create tag number 101-FY-100 as follows:

    1. Select the I/P Transducer (Flow), description for instrument type FY (General process function).

    2. On the Tag Number Properties dialog box, complete the definitions as shown.

  17. After completing all your tag definitions, click OK to close the dialog box.

    In the Domain Explorer, your loop and instruments should now appear as shown:


The spec document number 101-FT-100-SP has been created automatically with tag number 101-FT-100 because the instrument type profile of this tag includes a specification.