Rule: Panel Name must start with FCS then [01-31] then [01-64] for DCS/Centum CS 3000
Rule action: Check data.
Priority: 1(low).
Component 1: Panel.
Filter Information:
-
[Operand1] Panel; [Property] Panel Category; [Operator] =; [Operand2] Value; [Property/Value] DCS; [Logical Operator] And
-
[Operand1] Panel; [Property] Panel Manufacture; [Operator] =; [Operand2] Value; [Property/Value] Centum CS 3000; [Logical Operator] And
-
[Operand1] Panel; [Property] Plant/Reference Panel; [Operator] =; [Operand2] Value; [Property/Value] Plant
Consistency information:
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 1; [Length] 3; [Copy] None; [Compare] =; [Operand2] Value; [Property/Value] FCS; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 4; [Length] 1; [Copy] None; [Compare] Not Empty; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 4; [Length] 2; [Copy] None; [Compare] >=; [Operand2] Value; [Property/Value] 1; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 4; [Length] 2; [Copy] None; [Compare] <=; [Operand2] Value; [Property/Value] 31; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 6; [Length] 1; [Copy] None; [Compare] Not Empty; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 6; [Length] 2; [Copy] None; [Compare] >=; [Operand2] Value; [Property/Value] 1; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Substring; [Start] 6; [Length] 2; [Copy] None; [Compare] <=; [Operand2] Value; [Property/Value] 64; [Action] Error
-
[Operand1] Panel; [Property] Panel; [Function] Length; [Copy] None; [Compare] <=; [Operand2] Value; [Property/Value] 7; [Action] Error