When generating a Panel-Strip report, it is possible to specify whether or not to display grouping of channels, wiring equipment, and I/O channels. To do so, you need to specify a set of parameters in the Custom preferences for wiring.

  1. In the Wiring module, select File > Preferences.

  2. On the Preferences dialog, under Wiring, select Custom.

  3. In the Custom features for the Wiring module group box, under Parameter, type Display Channels.

  4. Under Value, type a string that consists of three digits made up of 0 and 1, for example, 110. In the string, the first digit refers to grouping of channels, the second digit refers to wiring equipment, and the third digit refers to I/O channels. The digit "1" instructs the software to display the channels and the wiring equipment. Zero means not to display the channels or the wiring equipment. For example, if you type 001, the software will display the I/O channels only. If you type 110, the software will display the grouping of channels and the wiring equipment items but it will not display the I/O channels. The default setting is 010, which displays wiring equipment items only.