Set the Maximum Number of Cables for the Standard Positions - Intergraph Smart Instrumentation - Help

Intergraph Smart Instrumentation Help

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Help
Smart Instrumentation Version
13.1

The maximum number of cables is a value that you define to limit the number of cables that you can associate with a position within a trunk section. You can add positions to trunks only if you predefined a maximum number of cables per position. That is, you define the number of cables for a standard position and only then the position becomes available to include in a trunk.

  1. In the Wiring Module window, select Tables > Cable Routing > Maximum Number of Cables.

  2. On the Maximum Number of Cables dialog, select a field and type the maximum number of cables in the width column of the required position.

    The grid displays the standard positions and standard widths that you have added to your current <plant>.

  3. Select OK to save your changes and close the dialog.