Create a Maintenance Event Record - Intergraph Smart Instrumentation - Help

Intergraph Smart Instrumentation Help

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Help
Smart Instrumentation Version
13.1
  1. Press F7 to open the Domain Explorer and then expand the hierarchy to the instrument level in the Instruments folder.

  2. Select an instrument for which you want to create a maintenance event record. The instrument that you select must belong to one of the following classes: Conventional, Fieldbus, HART, or Profibus.

  3. Right-click the Maintenance Events folder and on the shortcut menu select New > Maintenance Event Record.

    You can create one maintenance event record at a time.

  4. Under Maintenance event date, define the date of the event.

    When you define the date, the software automatically displays the record name in the Record name box, according to the preferences you set. For details, see Calibration and Maintenance > General (Preferences).

  5. In the Maintenance event description box, type and optional description.

    The description does not appear automatically on the record sheet. To display the description on the record sheet, you need to regenerate the form page on which the record is based and add the wa_prob_desc field in the page.

  6. Under Form number, select a form whose process function is the same as the process function of the source instrument.

  7. Select OK to create the record and display it in the Maintenance Events folder. It is indicated as an active record by PPM All Outputs Graphic.