Press F7 to open the Domain Explorer, and expand the hierarchy to the hook-up type level in the Hook-Ups folder.
-
In the Explorer tree view select the Hook-Ups folder, and right-click one or more specific hook-up type.
-
On the shortcut menu, select Actions > Associate with Instrument Types.
-
On the dialog that opens, the software displays all the instrument types defined in the current domain. You can associate the same instrument type with more than one hook- up type.
-
In the dialog panes, you can double-click a column header to sort the items in ascending order. Double-click again to sort the items in a descending order.
-
-
Under Available instrument types, select one or more instrument types and do one of the following:
-
Select Associate.
-
Drag the selected items to the Associated instrument types pane.
Electrical tags created in Smart Instrumentation cannot be associated with a Hook-Up even if the instrument type SPEL has been associated with the Hook-Up type. The SPEL instrument type is only for use with items retrieved from Smart Electrical in an integrated environment.
-
-