In the Instrument Index module, create a new function block.
-
In the Specifications module, open the Page Editor.
-
On the Page Editor toolbar, select .
-
On the Select Specification Page dialog, select Fieldbus Page.
-
Select Actions > Edit Fields and Headers .
-
On the Edit Fields and Headers floating toolbar, select to view the names of the data field on the specification page.
-
On the Edit Fields and Headers floating toolbar, select .
-
In the Table Column List pop- up window, select a table column starting with the string fb and containing a value between 22 and 40, for example, fb22_exists. For each custom function block, the following column types are available:
-
fb<number>_name — Displays the text string used for the function block label as defined in the Function Blocks supporting table.
-
fb<number>_count — Allows you to specify the number of function blocks of the type that are used in the instrument if the Multiple check box is selected in the Function Blocks dialog.
-
fb<number>_ex_time — Allows you to specify the execution time for the function block type if the Execution time check box is selected in the Function Blocks dialog.
-
fb<number>_exists — Displays a text box that you can select to indicate that the function block is required for the instrument.
The <number> value corresponds to the order in which you add custom function blocks in the Function Blocks supporting table, and not their alphabetic sequence.
-
-
Drag the table column value that you selected from the Table Column List pop-up window to the location on the currently open page.
-
Drag other custom function block values onto the page.
-
Select to close the Table Column List pop-up window.