Create a Connector - Intergraph Smart Instrumentation - Help

Intergraph Smart Instrumentation Help

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Help
Smart Instrumentation Version
13.1

Connectors are needed for fieldbus home-run cables, telecom cables, and other cables that require connectors. Smart Instrumentation allows you to build your wiring system with any of the following connector implementations:

  • Connector at one or both cable ends

  • Connector at end of a single cable set

  • Connector at end of wires from different cable sets

  1. In the Domain Explorer or Reference Explorer, do one of the following:

    • To create a new cable, right-click the Cables folder and select New > Cable.

    • Right-click an existing cable, and select Properties.

  2. Modify cable properties as needed. For details, see Create a Cable.

  3. Select Connectors.

  4. In the Connector Assignments dialog, select which cable end, End 1 or End 2, to manage connector-wire associations.

  5. In the Connector Assignments dialog, select New.

  6. In the Connector Properties dialog that opens, under Connector, type the name of the new connector.

  7. Under Male/female select Male or Female as needed.

  8. Select OK to return to the Connector Assignments dialog.