Create a wiring equipment item in the Reference Explorer.
-
In the Specifications module, restore a form associated with the Wiring Equipment item type.
-
In the Page Editor, open a spec page based on the form that you restored.
-
Regenerate the page, and from the APPARATUS table, add the appropriate APPAR_UDF columns as data fields in the page.
-
In the page, name the column headers to match the headers that you defined for wiring equipment properties in the Wiring module.
-
To display a list of headers, you need to open an external .psr file WIRING_EQUIPMENT_UDF.PSR, which is located in the path <Smart Instrumentation home folder> \PSR. You can open the file WIRING_EQUIPMENT_UDF.PSR using InfoMaker.
-
After adding custom fields in a spec page, you must change the column headers in the page so that they match the user- defined property names in the Wiring Equipment Category Properties dialog, which you access for the Wiring module (with the Wiring module main window open, select Tables > Wiring Equipment > Categories).