Wiring Item Naming Options Dialog Box - Intergraph Smart Instrumentation - 13.1 - Administration & Configuration - Hexagon PPM

Intergraph Smart Instrumentation Administration

PPMProduct
Intergraph Smart Instrumentation
PPMCategory_custom
Administration & Configuration
Version_SPI_custom
13.1

Enables you to set naming options for wiring items in the target lowest plant hierarchy item (for example, a unit) when copying data from one lowest plant hierarchy item to another.

 Wiring item naming settings are not retained when you reopen the Copy Data from Source dialog box.

Control system tag — Names new control system tags according to target tag names.  If you clear this check box, the software names new controls system tags according to source tag names.

Device panel — Allows you to set new names for the target device panels by selecting an option from the Like list.

Like — Allows you to select one of the following options for copying device panel names:

  • Default — Copies the device cables with the default names (identical with tag number names).

  • Naming Convention — Copies the device panels with the naming convention of the target <unit>.

 Clear this check box if you want to copy all device panels without changing the source names.  In this case, the copied device panels are named according to the settings you make for copying wiring items in the Copy Data from Source dialog box.

Device cable — Allows you to set new names for the target device cables by selecting an option from the Like list.

Like — Allows you to select one of the following options for copying device cable names:

  • Default — Copies the device cables with the default names, for example, C-<TAG NUMBER>.

  • Naming Convention — Copies the device cables with the naming convention of the target <unit>.

 Clear this check box if you want to copy all device cables without changing the source names.  The copied device cables are named according to the settings you make for copying wiring items in the Copy Data from Source dialog box.

Signal name — Copies signals using target tag names.  If you clear this check box, the software copies signals according to the settings you make for copying wiring items in the Copy Data from Source dialog box.

Wire tag — Copies wire tags using target tag names.  If you clear this check box, the software copies wire tags according to the settings you make for copying wiring items in the Copy Data from Source dialog box.

OK — Returns to the Copy Data from Source dialog box, where you can copy the <unit> data.