Enables the Domain Administrator to import third party interfaces to Smart Instrumentation.  These interfaces allow the Domain Administrator to transfer data to and from a third-party system, such as Fisher, Masoneilan, or Smart P&ID.  You can either import external import links and the appropriate source codes or import source codes only.

To access this dialog box, click Add-Ins > Import System Interfaces.

Source

File name and path — Allows you to specify the source file.  You can type the file name and path or click Browse.  The default file is In_ctlog.ddti.

Open — Opens the source file.

Import

Link group source file path — Allows you to specify the link group source file path.  You can enter the full path manually or click Browse.

Select link group — Displays all available link groups after you click Import.  Select a link group and click Import.

Import only source codes — Allows you to import only the source codes.

Import typical instruments — Allows you to include typical instrument data.

Import — Imports the selected link group from the source file to your database.  The button becomes accessible after you click Open.