Install Smart Engineering Manager in Silent Mode - Intergraph Smart Engineering Manager - 11 - Installation & Upgrade - Hexagon

Intergraph Smart Engineering Manager Installation and Upgrade

Language
English
Product
Intergraph Smart Engineering Manager
Search by Category
Installation & Upgrade
Smart Engineering Manager Version
11
  • At each workstation on which you want to install the software, open a Command Prompt window and type the silent installation command according to the following syntax:

    "<setup source folder path>\SPEM_setup.exe" /install /silent INSTALLFOLDER="<path>" /log "<log file path and name>.log" SLAACCEPT="YES" ADDLOCAL="ALL"

    Ensure that the command line includes spaces where shown before and after arguments.

    • Double quotes are required only if the path to the setup file contains spaces.

    • Argument values are case sensitive.

    • Mandatory arguments are validated by the setup procedure. If an argument or option is missing, the setup stops and a log is produced with the name of the missing argument.

      Example command line for Smart Admin installation:

      "\\SPEMInstall\Setup Files\SPEM_setup.exe" /install /silent INSTALLFOLDER="C:\Program Files (x86)\SmartPlant" /log" C:\Setup.log" SLAACCEPT="YES" ADDLOCAL="ALL"

      Pause

Command Line Arguments

Argument

Description

Mandatory

Notes

<setup source folder path>

The path to the file that launches the setup

Yes

SPEM_setup.exe

The name of the file that launches the setup

Yes

-install

Install product

No

-uninstall

Uninstall product

No

-repair

Repair product

No

-modify

Modify product features

No

-s, -silent

Silent mode

Yes

This argument is required for silent mode installation, together with the mandatory custom command line arguments; otherwise, the installation user interface is displayed.

-l, -log

Specifies a log file

No

If the log argument is used, a valid file path and name must be specified.

INSTALLFOLDER

Specifies the installation folder

No

The default installation folder should be set in bundle.wxs. If no value is specified, the default installation folder path is: "C:\Program Files (x86)\SmartPlant\".

SLAACCEPT

Approve license agreement

Yes

Accepted value: YES

USERNAME

Sets the user name

See 'Notes'

This argument is mandatory for an Evaluation Mode installation

COMPANYNAME

Sets the company name

See 'Notes'

This argument is mandatory for an Evaluation Mode installation

ADDLOCAL

The value of the ADDLOCAL argument is a list of features that are to be installed locally. If the ADDLOCAL argument is not present in the command line, the software installs features according to the default settings (for details, see the Notes below).

No

For use with the /install and /modify arguments.

Accepted values:

  • ALL — installs all available features

  • Specified list of features delimited by commas. The features must be present in the Feature column of the Feature table. The features available for this product are listed in the Notes below.

REMOVE

The value of the REMOVE argument is a list of features that are to be removed or excluded when modifying an installation.

No

For use with the /modify argument.

Accepted values: Specified list of features delimited by commas. The features must be present in the Feature column of the Feature table. The features available for this product are listed in the Notes below.

  • Command line arguments and their values are case-sensitive; therefore, you must ensure that they are typed exactly as shown in the above table.

  • Each command line argument must be preceded by a '-' or '/' delimiter, for example: -install - silent or /install / silent

  • If none of the arguments: install, uninstall, repair, or modify is specified, install is assumed as the default.

  • The ADDLOCAL = "ALL" argument installs all the basic and optional features listed in the tables below.

Basic Features

The basic features are the same as those selected by default in the regular interface.

All the features in this table are installed by default if the ADDLOCAL argument is not present in the command line.

Feature

Argument Value

Notes

Smart Engineering Manager

ENGINEERINGMGR

Smart Engineering Manager is always installed regardless of whether this argument is specified for ADDLOCAL. To install this feature alone, use the syntax ADDLOCAL = "ENGINEERINGMGR".

The REMOVE argument cannot be used for this feature.

Catalog Manager

CATALOGMGR

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Data Dictionary Manager

DATADICTMGR

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Data Dictionary Comparison Utility

DDTCOMPARE

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Filter Manager

FILTERMGR

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Format Manager

FORMATMGR

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Reference Data Synchronization Manager

RDSMGR

Use with ADDLOCAL to install this feature or with REMOVE to remove or exclude this feature when modifying the installation.

Optional Feature

Feature

Argument Value

Notes

Upgrade Utility

UPGRADEUTIL

This feature is not installed unless ADDLOCAL is present in the command line. Use with REMOVE to remove or exclude this feature when modifying the installation.

To install specific features, use the syntax: ADDLOCAL="FEATURE1,FEATURE2", for example: ADDLOCAL="CATALOGMGR,UPGRADEUTIL". To skip or remove specific features, use the syntax: REMOVE="FEATURE1,FEATURE2", for example: REMOVE="RDSMGR,FILTERMGR".

  • After a successful installation, you may be required to restart the computer.

  • If a mandatory parameter or value is missing or the value is incorrect, the installation will stop and an error will be recorded in the log file. It is recommended that after installation, you check the .log file to ensure that the installation proceeded without errors. If the silent installation was successful, at the end of the .log file, the following string appears:

    Exit code: 0x0