Define a Terminal Strip Configuration for a Single Terminal Strip - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10

This procedure explains how to define a terminal strip configuration for a terminal strip you are currently editing. Note that the software does not retain the configuration that you define. The software uses this configuration to create the terminals on the current terminal strip but does not store the configuration in the database.

  1. On the Terminal Strip Properties dialog, under Terminal strip configuration, enter the total number of terminals.

  2. Under First terminal, enter an appropriate value.

  3. In the Terminal strip pattern data grid, select and type in the Prefix field, select and type a value if you want to prefix the names of the terminals.

  4. Select the Numbered check box if you want the number of the terminal to appear between the prefix and the suffix.

  5. Select the Incremented check box if you want the terminal number to be incremented within the pattern.

  6. In the Suffix field, select and type a value if you want a suffix for the names of the terminals.

  7. Select Add if you want to add another data row in the terminal strip pattern. The maximum number of rows that you can add cannot exceed the total number of terminals that you enter.

  8. Select OK.