Create or Replace Cable Side Associations in Batch Mode - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10

This procedure explains how to create or replace the cable end connections for a group of non-power cables. It is useful where a large number of cables are connected to the same marshaling rack or cabinet, or when you want to add end connections to a large number of cables that have no end connections.

  1. In the Electrical Index, expand the folder hierarchy Wiring Equipment > Cables.

  2. Select the required cable folder: Control Cables, Grounding Cables, or Instrumentation Cables. You cannot perform this operation for power cables.

  3. In the lower pane, select the required cables that you want to add end connections to, or whose end connections you want to replace.

  4. Select Actions > Cables > Batch Cable Side and Gland Associations.

  5. Skip this step if you are creating end connections.

    On the From or To cable side, clear the Dissociate existing connection check box to allow replacement of existing cable associations for the cables that you select.

  6. Select Find to open the Find dialog.

  7. From the Equipment type list, select the required equipment type.

  8. Select Find Now.

  9. In the Results data window, select the item that you want to associate with the cable sides, and select OK.

  10. From the cable list in the Batch Cable Side and Gland Associations dialog, select the check boxes beside the cables for which you want to make cable side associations.

  11. Select OK.