Structure of the component register template - Intergraph Smart Construction - 2019 (7.0) - Help - Hexagon PPM

Intergraph Smart Construction Help (2019)

Language
English
Product
Intergraph Smart Construction
Search by Category
Help
Smart Construction Version
2019(7.0)
SmartPlant Foundation / SDx Version
10

Each delivered Smart Construction component register template contains three tabbed workbooks. Each tab defines different features of the register.

Main tab

The Main tab is located on the first sheet of the workbook, and it contains the Generate [Register name] File button, which generates the XML load file. The load file can be loaded into your Smart Construction data warehouse site as a design document.

Do not rename or remove the Generate [Register name] File button. Do not modify or remove the code behind the button.

[Register Name] tab

The [Register Name] tab specifies the name of the delivered register, and it contains configuration details for the register.

Column Header

Explanation

Column Description

Identifies the names of columns in the Data tab.

InterfaceDef

Defines the interface definition for the property.

PropertyDef

Defines the property definition for the property.

Notes

Defines the data format required for data in the register.

Rules

Lists the validation rules associated with the register.

Required

Specifies whether the data is required for a successful import of data.

Comments

Provides a box for comments and details.

Data tab

Each component register template contains a Data tab, which details the data to be generated. These details are then associated to the component register document that is retrieved into Smart Construction. The data column headings are unique to each register template delivered with Smart Construction. For more information on specific delivered registers, see Delivered SmartPlant Construction component register templates.

The following details apply to the Data tab for all delivered Smart Construction register templates.

  • The template column headings specifying the register details appear in the sixth row. The register header is contained in the first five rows of the register. Data for the register template must be defined in rows seven and below.

  • The unit must be spelled the exact same (with same capitalization) as the unit specified on the Register Syntax tab.

  • Type a description in the Description column of the Generic Register, Cable Description column of the Cable Schedule register, or Column Description column of the Instrument Index register to associate material items in the Material Request form. The tag item description is used as the material description in the Material Request form.

Register Syntax tab