Vertical corner brace frame connection is related to something other than the second supporting member system. Change connection to unsupported and then re-select the supporting members. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: The corner brace's second supporting member was not a member system, resulting in the improper placement of the corner brace. This error is an internal software failure where the calling software did not properly call the frame connection with its required inputs.

Recovery:

  1. Select the frame connection in error.

  2. Select By Rule from the Connection box on the Properties View.

  3. Redefine the end location of the brace by selecting the frame connection of the supporting beam.