Axis-collinear frame connection is invalid because the previous connection was not removed. Change connection to unsupported and the re-select the supporting member. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: The axis-collinear connection is invalid because the member's frame connection was converted to an axis-collinear connection from another connection type without first re-initializing the frame connection. This error is an internal software failure where the calling software did not first re-initialize the frame connection as an unsupported frame connection.

Recovery:

  1. Select the frame connection in error.

  2. Select By Rule from the Connection box in the Properties View.

  3. Redefine the end location of the member.