Meaning: Inconsistent relations where the input end port of the supporting member does not match the related end port of the axis collinear connection. This is an internal software failure where the axis collinear connection was defined incorrectly.

Recovery:

  1. Select the frame connection in error.

  2. Select By Rule from the Connection box in the Properties View.

  3. Redefine the end location of the member.