Meaning: The name of the Drawings by Query Manager Component is identical to the focus objects in the drawing. The focus object in the model was renamed by a user without access permission to the drawing (due to Permission Group access or Working status).
Recovery:
-
Manually update the drawing, or select Run Query on the Drawings by Query Manager component to clear the To Do List entries.
-OR-
-
A user with access to the drawing permission group must click Synchronize out of date occurrences in workspace on the Window Tab.
Smart 3Dx displays the Synchronize Workspace with Catalog Dialog.
-
Select the object in error, and then click Update.
The software updates the object and removes it from the To Do List.
-OR-
-
Change the drawing Status to Working in the Properties View .
-
Click Synchronize out of date occurrences in workspace on the Window Tab.
Smart 3Dx displays the Synchronize Workspace with Catalog Dialog.
-
Select the object in error, and then click Update.
The software updates the object and removes it from the To Do List.