Seated frame connection was re-verified and found to be invalid. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: Re-verification of the seated connection indicates that it was not established correctly. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error. \

  5. Select More from the Connection box on the ribbon.

  6. Click Seated in the tree view.

  7. Select the seated connection that you want (top, bottom, left, or right).

  8. Redefine the end location of the member.