Meaning: Improper placement of the corner brace where the corner brace's frame connection was a different type and was converted to a vertical corner brace without first re-initializing the frame connection. This error is an internal software failure where the software did not first re-initialize the frame connection as an unsupported frame connection.

Recovery:

  1. Select the frame connection in error.

  2. Select By Rule from the Connection box on the Properties View.

  3. Redefine the end location of the brace by selecting the frame connection of the supporting beam.