Select Piping Tab > Quick Pipe Command to display the Quick Pipe Controls.
-
Select the location on the straight feature to start the bypass.
-
Select the location on the straight feature to end the bypass.
The software displays all possible path options based on the location of the two locations.
-
Select the Path Options to use.
-
Select the pipe run for the bypass. You can select the pipe run several ways:
-
Select Select to select an existing run in a graphic view or in the System hierarchy.
-
Select Select from P&ID to select the run from a P&ID drawing.
-
Select New Pipe Run to create a new pipe run to route. See Pipe Run Controls.
-
Select More to select a pipe run that is associated with a different pipeline parent. See Select Run Dialog.
-
Select a recently used pipe run from the list.
-
-
Select and edit the Depth value as required. If the dimension box does not display, select Menu > Options Dialog > General Tab > Display dynamically, or press D on your keyboard.
-
Complete the placement:
Select Finish or press CTRL + ENTER to save your changes and exit the command.
Select Finish and Repeat or press SHIFT + ENTER to save your changes and then restart the command using the same options.
The software places the bypass.