Meaning: The Synchronize Model with Catalog command in Project Management was run while the object was read-only. The object was read-only either because the Status was set to something other than Working, or the user who ran the synchronization did not have write permission to the object.
Recovery: If the cause was the object having a status not set to working:
-
Select the object in error.
-
Change the Status of the object to Working.
-
Start Project Management.
-
Click Tools > Synchronize Model with Catalog.
-
Alternatively, click View > To Do List.
-
On the To Do List dialog box, select the object, and click Update .
The software updates the object and removes it from the To Do List.
If the cause was the user not having write permission to the object:
-
Start Project Management as a user with write access to the object.
-
Click Tools > Synchronize Model with Catalog.
-
If you have a global workshare configuration, run Synchronize Model with Catalog at each location.