Place two types of fireproofing on a single member - Intergraph Smart 3D - Help

Intergraph Smart 3D Structure

Language
English
Product
Intergraph Smart 3D
Subproduct
Structure
Search by Category
Help
Smart 3D Version
12 (2018)
  1. Click Place Fireproofing Command on the vertical toolbar.

  2. Clear the By Rule option to set the fireproofing properties.

  3. Select the member to which you want to apply the different types of fireproofing.

  4. Set Condition to Add.

  5. In the Insulation Spec box, select the first insulation specification to use.

  6. In the Encasement box, select the first encasement to use.

  7. Define the fireproofing setbacks that you need for this fireproofing using the Reference 1, Distance 1, Reference 2, and Distance 2 boxes.

  8. Click Accept .

  9. Verify the fireproofing is where you want it on the member. Adjust the setback properties if needed.

  10. Click Finish to place the first fireproofing type.

  11. Visually verify that the member is still selected (yellow highlighted). If it is not highlighted, select the member again.

  12. Change the insulation specification and encasement as needed for the second type of fireproofing that you want to place on the member.

  13. Define the fireproofing setbacks for the second type using the Reference 1, Distance 1, Reference 2, and Distance 2 boxes.

  14. Click Accept .

  15. Verify the fireproofing is where you want it on the member. Adjust the setback properties if needed to keep it from overlapping the first fireproofing that you placed.

  16. Click Finish to place the second fireproofing type.