Parameters Tab (Physical Connection Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Structural Detailing

Language
English
Product
Intergraph Smart 3D
Subproduct
Structural Detailing
Search by Category
Help
Smart 3D Version
11 (2016)

Specifies the parameters for the smart occurrence object.

Parameter

Displays the name of the parameter.

Value

Displays the value of the parameter. Values that are grayed cannot be modified.

Rule-Based

Displays a check box if the parameter value is rule-based. Clear the check box to modify the value in the Value box.

Catalog Value

Displays the original catalog value if the Value box has been modified.

Welding Symbol Parameters

In addition to physical connection parameters, welding symbol parameters are also visible. Weld symbols are used by the Drawings and Reports task but welding symbol parameters are only visible on the Parameters tab for a physical connection:

1 - Primary Side Symbol or Primary Side Groove

13 - Secondary Side Pitch or Distance Between the Ends of Adjacent Welds

2 - Secondary Side Symbol or Secondary Side Groove

14 – Primary Side Contour

3 – Primary Side Groove Size

15 – Secondary Side Contour

4 – Secondary Side Groove Size

16 – Primary Side Finish Method

5 - Primary Side Bevel Depth or Leg Length or Actual Throat Thickness or Strength

17 – Secondary Side Finish Method

6 - Secondary Side Bevel Depth or Leg Length or Actual Throat Thickness or Strength

18 – Primary Side Root Opening or Depth of Filling

7 – Field Weld

19 - Secondary Side Root Opening or Depth of Filling

8 - All Around

20 – Primary Side Groove Angle or Included Angle of Countersink

9 – Tail Notes

21 - Secondary Side Groove Angle or Included Angle of Countersink

10 – Primary Side Length

22 – Primary Side Number Of Welds

11 – Secondary Side Length

23 - Secondary Side Number Of Welds

12 – Primary Side Pitch or Distance Between the Ends of Adjacent Welds

The actual parameters provided depend upon the type of physical connection, but the following figures are representative.See physical connection reference data in Structural Detailing Reference Data.

The following example shows the welding symbol properties for a Y tee weld. Other tee welds and lap welds are similar.

The next example shows the welding symbol parameters for a V butt weld. Fewer of the parameters are exposed because many are not applicable to a butt weld.