Even though an assembly output has been declared, it does not imply that you must create an output. Not constructing an output indicates the output is not required. Additionally, if an output already exists you can remove the output:

If m_oPierAssemblyOutput.Output Is Nothing Then

m_oPierAssemblyOutput.Delete()

End If