The Geometry Type select list (codelist) defines the geometric characteristics and the topology of the piping ports for piping parts. You must specify the correct geometry type so that the software knows how to handle the item when placing it in the model.

This select list is used in the reference data for the Piping task when defining piping instruments and specialty item parts. The list belongs to the REFDAT namespace. You can use this list to map the Component Geometry to Route Feature Type.

You can edit the delivered text of the short or long descriptions as long as you do not change the meaning. Do not change the numeric values of the delivered select list items. You cannot add or delete select list items.

Number

Short Description

Long Description

Route Feature Type

Picture of a Typical Component

Description

Placement Restrictions

5

Variable length pipe stock or tubing

Plain piping or tubing variable length

SF

 

 

This value applies to pipe stock or tubing, where the length is not constrained by a purchase length.

 

10

Fixed length pipe stock or tubing

Plain piping or tubing fixed length

SF

 

This value applies to pipe stock or tubing, where the length is constrained by a purchase length.

 

11

Variable length integral core and jacket piping

Integral core and jacket piping Variable length

ALF_COMPONENT

 

 

This value applies to pipe stock, which represents a jacket integral with the core, where the length is not constrained by a purchase length.

Can be placed in a straight or on an end port.

15

Linear, full-size

Linear, full size

ALF_COMPONENT

 

 

This value applies to any fitting or valve, where the ports are collinear and of equal size, for example, a gate valve or a flange.

Can be placed in a straight or on an end port.

16

Linear, with size change

Linear, with size change

ALF_RUNCHANGE

 

This value applies to any fitting or valve, where the ports are collinear, but the sizes differ, for example, a concentric reducer or concentric swage.

Can be placed only on an end port.

20

Elbow, fixed angle

Elbow, fixed angle (including angle valves)

DC_ELBOW

 

SP3D RefD Geometry Type 20

This value applies to any full-size change-of-direction fitting, where the bend angle is constant, that is, the elbow cannot be trimmed, for example a flanged elbow.

Can be placed only at an end port.

25

Elbow, fixed / trimmable angle

Elbow, trimmable

DC_ELBOW

SP3D RefD Geometry Type 25

This value applies to any full-size change-of-direction fitting, where the elbow can be trimmed.

Can only be placed at an end port.

30

Elbow, side outlet

Elbow, side outlet

DC_ELBOW

SP3D RefD Geometry Type 30

This value applies to any full-size change-of-direction fitting with a side outlet.

Can only be placed at an end port.

35

Elbow, radial outlet

Elbow, radial outlet

DC_ELBOW

SP3D RefD Geometry Type 35

This value applies to any full-size change-of-direction fitting with a radial outlet.

Can only be placed at an end port.

36

Elbow, reducing

Elbow, reducing

DC_REDUCINGELBOW

 

SP3D RefD Geometry Type 36

This value applies to any reducing change-of-direction fitting.

Can only be placed at an end port.

37

Elbow, gooseneck

Elbow, gooseneck

ALF_ENDLEG

 

SP3D RefD Geometry Type 37

This value applies to any full-size gooseneck fitting, for example, a standpipe gooseneck.

Can only be placed at an end port.

40

Return

Return

ALF_ENDLEG

SP3D RefD Geometry Type 40

This value applies to any 180° return fitting.

Can only be placed at an end port.

45

Return, bottom outlet

Return, bottom outlet

ALF_ENDLEG

SP3D RefD Geometry Type 45

This value applies to any 180° return fitting with a bottom outlet, for example, a biological-pharmaceutical use point with a bottom outlet.

Can only be placed at an end port.

50

Return, side outlet

Return, side outlet

ALF_ENDLEG

SP3D RefD Geometry Type 50

This value applies to any 180° return fitting with a side outlet, for example, a biological-pharmaceutical use point with a side outlet.

Can only be placed at an end port.

55

Pipe bend

Pipe bend

DC_BEND

 

 

Can only be placed at an end port.

60

Mitered elbow (pre-fabricated part to be purchased)

Miter

DC_MITER

 

SP3D RefD Geometry Type 60

This value applies to any pre-fabricated, mitered, change-of-direction fitting.

Can only be placed at an end port.

65

Eccentric, with size change

Eccentric size change

ALF_RUNCHANGE

 

SP3D RefD Geometry Type 65

This value applies to any fitting or valve, where the inline ports are offset, but the sizes differ, for example, an eccentric reducer or eccentric swage.

Can only be placed at an end port.

66

Eccentric, full size

Eccentric, full size

ALF_RUNCHANGE

 

This value applies to any fitting or valve, where the inline ports are offset and of equal size, for example an expansion joint with an offset.

Can only be placed at an end port.

70

Concentric size change

Concentric size change

ALF_RUNCHANGE

SP3D RefD Geometry Type 70

This value applies to any fitting or valve, where the ports are collinear, but the sizes differ, for example, a concentric reducer or concentric swage.

Can only be placed at an end port.

75

Tee, full size (including 3-way valves)

Tee, full size (including 3-way valves)

BP_HEADER

 

 

This value applies to any full-size tee-type branch fitting or 3-way valve.

Can be placed in a straight or on an end port.

80

Tee, reducing branch

Tee, reducing branch

BP_HEADER

 

This value applies to any tee-type branch fitting or 3-way valve with a reducing branch.

Can be placed only on an end port.

85

Tee, eccentric reducing branch

Tee, eccentric reducing branch

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with an eccentric reducing branch.

Can be placed only on an end port.

90

Tee, reducing run and branch

Tee, reducing run and branch

BP_HEADER

SP3D RefD Geometry Type 90

This value applies to any tee-type branch fitting or 3-way valve with a reducing run and a reducing branch.

Can be placed only on an end port.

95

Tee, reducing runs

Tee, reducing runs

BP_HEADER

 

This value applies to any tee-type branch fitting or 3-way valve with two reducing run legs, for example, a bullhead tee.

Can be placed only on an end port.

100

Tee with offset, full size

Tee with offset, full size

ALF_COMPONENT

 

This value applies to any full-size tee-type branch fitting or 3-way valve with an offset.

Can be placed only on an end port.

105

Tee with offset, reducing branch

Tee with offset, reducing branch

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with an offset and a reducing branch.

Can be placed only on an end port.

110

Tee with offset, reducing run and branch

Tee with offset, reducing run and branch

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with an offset, a reducing run, and a reducing branch.

Can be placed only on an end port.

115

Tee with offset, reducing runs

Tee with offset, reducing runs

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with an offset and two reducing runs.

Can be placed only on an end port.

120

Tee with double offset, full size

Tee with double offset, full size

ALF_COMPONENT

 

This value applies to any full-size tee-type branch fitting or 3-way valve with a double offset.

Can be placed only on an end port.

125

Tee with double offset, reducing branch

Tee with double offset, reducing branch

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with a double offset and a reducing branch.

Can be placed only on an end port.

130

Tee with double offset, reducing run and branch

Tee with double offset, reducing run and branch

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with a double offset, a reducing run, and a reducing branch.

Can be placed only on an end port.

135

Tee with double offset, reducing runs

Tee with double offset, reducing runs

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with a double offset and two reducing runs.

Can be placed only on an end port.

140

Tee, non-symmetrical

Tee, non-symmetrical

ALF_COMPONENT

 

This value applies to any tee-type branch fitting or 3-way valve with non-symmetrical runs.

Can be placed in a straight or on an end port.

145

Cross, full size (including 4-way valves)

Cross, full size (including 4-way valves)

ALF_COMPONENT

SP3D RefD Geometry Type 145

This value applies to any full-size cross-type branch fitting or 4-way valve.

Can be placed in a straight or on an end port.

150

Cross, reducing branches

Cross, reducing branches

ALF_COMPONENT

SP3D RefD Geometry Type 150

This value applies to any cross-type branch fitting or 4-way valve with two reducing branches.

Can be placed in a straight or on an end port.

155

Cross, reducing run and one branch

Cross, reducing run and one branch

ALF_COMPONENT

 

This value applies to any cross-type branch fitting or 4-way valve with a reducing run and a reducing branch.

Can be placed only on an end port.

160

Cross, reducing run and two branches

Cross, reducing run and two branches

ALF_COMPONENT

 

This value applies to any cross-type branch fitting or 4-way valve with a reducing run and two reducing branches.

Can be placed only on an end port.

165

Lateral, full-size

Lateral, full size

BP_HEADER

SP3D RefD Geometry Type 165

This value applies to any full-size lateral-type branch fitting or valve.

Can be placed in a straight or on an end port.

170

Lateral, reducing branch

Lateral, reducing branch

BP_HEADER

SP3D RefD Geometry Type 170

This value applies to any lateral-type branch fitting or valve with a reducing branch.

Can be placed in a straight or on an end port.

175

Lateral, reducing run and branch

Lateral, reducing run and branch

BP_HEADER

 

This value applies to any lateral-type branch fitting or valve with a reducing run and a reducing branch.

Can be placed only on an end port.

180

Lateral reducing runs

Lateral reducing runs

BP_HEADER

 

This value applies to any lateral-type branch fitting or valve with two reducing runs.

Can be placed only on an end port.

185

Olet-type branch, fixed angle

Olet-type branch, fixed angle

BF_BRANCH

 

SP3D RefD Geometry Type 185

This value applies to any olet-type branch fitting, where the branch angle is constant, that is, the olet-type branch cannot be trimmed.

Can only be placed on a straight.

186

Olet-type branch, variable angle

Olet-type branch, variable angle

BF_BRANCH

 

This value applies to any olet-type branch fitting, where the olet-type branch can be trimmed.

Can only be placed on a straight.

187

Olet-type branch, double outlet

Olet-type branch, double outlet

ALF_COMPONENT

 

This value applies to any olet-type branch fitting with two outlets.

Can be placed only in a straight.

190

Latrolet®-type branch

Latrolet®-type branch

BF_BRANCH

SP3D RefD Geometry Type 190

This value applies to any olet-type branch fitting, where the acute branch angle is less than 90°.

Can only be placed on a straight.

195

Non-radial branch

Non-radial branch

BF_BRANCH

SP3D RefD Geometry Type 195

This value applies to any olet-type branch fitting, where the branch centerline is offset from the header centerline.

Can only be placed on a straight.

200

Endolet-type branch (Flatolet)

Endolet-type branch

ALF_COMPONENT

SP3D RefD Geometry Type 200

This value applies to any olet-type branch fitting that, due to the branch size being so small and the run size so large, the branch fitting is basically flat on the bottom.

Can be placed only in a straight.

205

Elbolet

Elbolet

ALF_RUNCHANGE

 

SP3D RefD Geometry Type 205

This value applies to any elbolet-type branch fitting, where the elbolet fitting is used to branch from a change-of-direction fitting.

Can only be placed at an end port.

210

True Y-type branch

True Y-type branch

ALF_ENDLEG

 

SP3D RefD Geometry Type 210

This value applies to any wye-type branch fitting or valve.

Can only be placed at an end port.

215

Double Y-type branch

Double Y-type branch

ALF_ENDLEG

 

SP3D RefD Geometry Type 215

This value applies to any double wye-type branch fitting or valve.

Can only be placed at an end port.

220

Closing fitting (including instrument indicators and instrument transmitters)

Closing (including instrument indicators)

EF_ENDFEATURE

 

 

This value applies to any closing fitting, for example, a cap, a plug, a blind flange, an instrument indicator, or an instrument transmitter. By definition, a closing fitting has one port.

Can only be placed at an end port.

225

Orifice flange

Orifice flange

ALF_COMPONENT

SP3D RefD Geometry Type 225

This value applies to any flange with three or more ports.

Can be placed in a straight or on an end port.

230

Multi-port valve

Multi-port valve

ALF_ENDLEG

SP3D RefD Geometry Type 230

This value applies to any multiport valve.

Can only be placed at an end port.

235

Surface-mounted

Surface-mounted

SMC_FEATURE

 

 

This value applies to any surface-mounted fitting other than a wall penetration fitting, for example a centering flange or a surface-mounted instrument.

Can only be placed on a straight.

240

Tandem valve, horizontal main at drain angle with vertical tandem

Tandem valve, horizontal main at drain angle with vertical tandem

ALF_COMPONENT

 

This value applies to any sanitary or aseptic tandem valve, where the drainage geometry is described in this manner.

Can be placed in a straight or on an end port.

245

Tandem valve, horizontal main with vertical tandem

Tandem valve, horizontal main with vertical tandem

ALF_COMPONENT

 

This value applies to any sanitary or aseptic tandem valve, where the drainage geometry is described in this manner.

Can be placed in a straight or on an end port.

250

Tandem valve, vertical main with tandem at drain angle

Tandem valve, vertical main with tandem at drain angle

ALF_COMPONENT

 

This value applies to any sanitary or aseptic tandem valve, where the drainage geometry is described in this manner.

Can be placed in a straight or on an end port.

255

Tandem valve, horizontal main with tandem at drain angle

Tandem valve, horizontal main with tandem at drain angle

ALF_COMPONENT

 

This value applies to any sanitary or aseptic tandem valve, where the drainage geometry is described in this manner.

Can be placed in a straight or on an end port.

256

Angle valve

Angle valve

ALF_ENDLEG

SP3D RefD Geometry Type 256

This value applies to any full-size, change-of-direction valve.

Can only be placed at an end port.

257

Angle valve, reducing

Angle valve, reducing

DC_REDUCINGELBOW

SP3D RefD Geometry Type 257

This value applies to any reducing, change-of-direction valve.

Can only be placed at an end port.

260

Valve fitting/assembly, horizontal valve with vertical fitting access

Valve/fitting assembly, horizontal main at drain angle with vertical access on primary side of center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

265

Valve fitting/assembly, horizontal valve at drain angle with vertical fitting access

Valve/fitting assembly, horizontal main at drain angle with vertical access on secondary side of center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

270

Valve fitting/assembly, horizontal valve at drain angle with horizontal fitting access

Valve/fitting assembly, horizontal main at drain angle with horizontal access at drain angle

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

275

Valve fitting/assembly, vertical valve with horizontal fitting access

Valve/fitting assembly, vertical main with horizontal access at drain angle below main center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

280

Valve/fitting assembly, vertical main with horizontal access at drain angle below main center and 45° from assembly center

Valve/fitting assembly, vertical main with horizontal access at drain angle below main center and 45° from assembly center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

285

Valve/fitting assembly, vertical main with horizontal access at drain angle above main center

 

Valve/fitting assembly, vertical main with horizontal access at drain angle above main center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

290

Valve/fitting assembly, vertical main with horizontal access at drain angle above main center and 45° from assembly center

Valve/fitting assembly, vertical main with horizontal access at drain angle above main center and 45° from assembly center

ALF_ENDLEG

 

This value applies to any sanitary or aseptic access valve with an access fitting assembly, where the drainage geometry is described in this manner.

Can only be placed at an end port.

295

Lift check valve, horizontal orientation only

Lift check valve, horizontal orientation only

ALF_COMPONENT

SP3D RefD Geometry Type 295

This value applies to any flow-dependent valve, where the valve can only be installed in a horizontal pipe run.

Can be placed only on an end port.

300

Lift check valve, vertical orientation only

Lift check valve, vertical orientation only

ALF_COMPONENT

SP3D RefD Geometry Type 300

This value applies to any flow-dependent valve, where the valve can only be installed in a vertical pipe run.

Can be placed in a straight or on an end port.

305

 

Fitting with multiple branches, e.g. bleed ring or drip ring tree

ALF_ENDLEG

SP3D RefD Geometry Type 305

This value applies to any circular fitting with multiple branches, for example, bleed ring or drip ring tee.

Can only be placed at an end port.

310

Wall penetration fitting

 

Wall penetration fitting

SMC_FEATURE

SP3D RefD Geometry Type 310

This value applies to any surface-mounted fitting, for example, a penetration sleeve, where the fitting is to be aligned with a hole in a wall or other structure.

Can only be placed on a straight.

315

Clamp-on fitting

 

Clamp-on fitting

SMC_FEATURE

SP3D RefD Geometry Type 315

This value applies to any clamp-on fitting, for example, a clamp-on saddle or a clamp-on flow sensor.

Can only be placed on a straight.

500

Generic

Generic

ALF_ENDLEG

 

This value applies to any other fitting.