Equipment to pipe run connections - Intergraph Smart 3D - Help

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
12.1 (2019)
SmartPlant Foundation / SDx Version
10

Flanged Connections

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Non-working

Full control/ Write

3

Base flange associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment. The software generates a to Do Record for the connection at the flange.

You must have Wrtie access on the flange connection to update the To Do Record.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Working

Full control/ Write

3

Mating flange associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment, including the mating flange and all associated connections with the pipe run.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Non-working

Full control/ Write

3

Mating flange associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run. The software generates a To Do Record for the mating flange, because it is in non-working state.

You must have Write access to the mating flange to update the To Do Record.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Non-working

Full control/ Write

3

Mating flange associated with the pipe run

4

Component associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment. The software generates a To Do Record for the component.

You must have Write access on the component to update the To Do Record.

Before deletion

After deletion

Welded Connections

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Non-working

Full control/ Write

3

Welded connection

Result: If the equipment is deleted, the software deletes the equipment. The software generates a To Do Record for the weld.

You must have Write access on the pipe run to update the To Do Record.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Working

Full control/ Write

3

Mating flanges associated with the pipe run

4

Component associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Equipment

-

Read-only

2

Pipe run

Non-working

Full control/ Write

3

Mating flanges associated with the pipe run

4

Component associated with the pipe run

Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run. The software generates a To Do Record for the mating flange, because it is in non-working state.

You must have Write access to the mating flange to update the To Do Record.

Before deletion

After deletion