  1. Click Route Flex Pipe Command Route Flex Pipe on the vertical toolbar.

  2. Select the run starting point. If you select an equipment nozzle, the software prompts you to create a new pipe run. If you select an equipment nozzle that is correlated with P&ID design basis data, the software automatically determines which run should be connected.

  3. On the New Pipe Run Dialog, type a name. If you do not specify a name, the software automatically generates a name. See Select pipe run settings.

  4. Click OK to close the dialog.

  5. Select the ending point of the flexible pipe.

  • If the piping specification that you selected has service limits defined, you must define at least one temperature value and one pressure value for the pipe run. Do this by selecting Temperature and Pressure from the Category option.