Route a pipe from a R3D port without making a connection - Intergraph Smart 3D - Help

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
11 (2016)
SmartPlant Foundation / SDx Version
10
  1. Locate the R3D port from which you want to route a pipe.

  2. Click Route Pipe Command on the vertical toolbar.

  3. Press and hold the S key.

  4. Move the mouse pointer over the R3D port until the Circle 3d glyph displays, and then click to route the pipe run.

  5. On the New Pipe Run Dialog, select the parent Pipeline. If there are no pipeline systems defined in the Workspace Explorer create a new pipeline system. Alternatively, select a pipeline system from the database to which you want to associate the new pipe run.

    The software does not display the Reference 3D tab.

  6. In the Name box, type a name for the pipe run. If you do not specify a name, the software automatically generates a name.

  7. Click OK to close the New Pipe Run Dialog.

  8. Continue routing.

    The software does not connect the pipe run to the R3D port.

  9. Right-click to end the routing.

See Also

Route an existing pipe from a R3D port without making a connection