Click Insert Component Command on the vertical toolbar.
-
Click the component on which to place the branch fitting.
-
On the ribbon, select the pipe run in which to insert the branch fitting.
-
In the Type box, select a branch component.
-
If necessary, specify the distance and reference port to position the branch fitting.
-
Click Component Orientation , and set the orientation for the branch fitting. This step is applicable if the base component is a turn feature (such as an elbow or pipe bend), ALF end leg, or end feature (cap, blind flange, and so forth).
-
Click Finish.
When you route from the branch fitting, the software automatically generates a tap. If you delete the branch fitting, the automatically generated tap also gets deleted.