Pipe run to pipe run connections - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
13
SmartPlant Foundation / SDx Version
10

Welded Connection

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

-

3

Welded connection

Result: If you delete pipe run A, the software deletes pipe run A, and associated connections. The software generates a To Do Record for the weld connection. You must have Write access on the weld connection to update the To Do Record.

Before deletion

After deletion

Flanged Connections

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

-

3

Base/Mating flange associated with pipe run A

4

Base flange associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software generates a To Do Record for the flange connection. You must have Write access on the flange to update the To Do Record.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Working

Read-only

3

Base flange associated with pipe run A

4

Mating flange associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including the mating flange, all associated objects and connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

Full control/ Write

3

Base flange associated with pipe run A

4

Mating flange associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A including all associated objects and connections. The mating flange remains, and the software generates a To Do Record for the mating flange. You must have Write access on the mating flange to update the To Do Record.

Before deletion

After deletion

Size Change Connections

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Working

Read-only

3

Mating reducer associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including the mating reducer and associated connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

Full control/ Write

3

Mating reducer associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including all associated connections. The reducer remains, and the software generates a To Do Record for the reducer. You must have Write access on the reducer to update the To Do Record.

Before deletion

After deletion

Flanged and Size Change Connections

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Working

Read-only

3

Mating reducer associated with pipe run B

4

Mating flange associated with pipe run A

5

Mating flange associated with pipe run B

6

Component associated with pipe run A

Result: If you delete pipe run A, the software deletes pipe run A, including the mating parts, all associated objects and connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

-

3

Mating reducer associated with pipe run B

4

Mating flange associated with pipe run A

5

Mating flange associated with pipe run A

6

Component associated with pipe run A

Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software does not delete the mating flange and generates a To Do Record for the mating flange. You must have Write access to the mating flange to update the To Do Record.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Working

Read-only

3

Base flange associated with pipe run A

4

Mating flanges associated with pipe run B

5

Mating reducer associated with pipe run B

6

Component associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including mating parts, all associated objects and connections.

Before deletion

After deletion

No.

Route Object

Approval Status

Permission Group Access

1

Pipe run A

Working

Full control/ Write

2

Pipe run B

Non-working

Full control/ Write

3

Base flange associated with pipe run A

4

Mating flanges associated with pipe run B

5

Mating reducer associated with pipe run B

6

Component associated with pipe run B

Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software generates a To Do Record for the mating flange. You must have Write access to the mating flange to update the To Do Record.

Before deletion

After deletion