Welded Connection
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
- |
|
3 |
Welded connection |
|||
Result: If you delete pipe run A, the software deletes pipe run A, and associated connections. The software generates a To Do Record for the weld connection. You must have Write access on the weld connection to update the To Do Record. |
||||
Before deletion |
After deletion |
Flanged Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
- |
|
3 |
Base/Mating flange associated with pipe run A |
|||
4 |
Base flange associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software generates a To Do Record for the flange connection. You must have Write access on the flange to update the To Do Record. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Working |
Read-only |
|
3 |
Base flange associated with pipe run A |
|||
4 |
Mating flange associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including the mating flange, all associated objects and connections. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
Full control/ Write |
|
3 |
Base flange associated with pipe run A |
|||
4 |
Mating flange associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A including all associated objects and connections. The mating flange remains, and the software generates a To Do Record for the mating flange. You must have Write access on the mating flange to update the To Do Record. |
||||
Before deletion |
After deletion |
Size Change Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Working |
Read-only |
|
3 |
Mating reducer associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including the mating reducer and associated connections. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
Full control/ Write |
|
3 |
Mating reducer associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including all associated connections. The reducer remains, and the software generates a To Do Record for the reducer. You must have Write access on the reducer to update the To Do Record. |
||||
Before deletion |
After deletion |
Flanged and Size Change Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Working |
Read-only |
|
3 |
Mating reducer associated with pipe run B |
|||
4 |
Mating flange associated with pipe run A |
|||
5 |
Mating flange associated with pipe run B |
|||
6 |
Component associated with pipe run A |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including the mating parts, all associated objects and connections. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
- |
|
3 |
Mating reducer associated with pipe run B |
|||
4 |
Mating flange associated with pipe run A |
|||
5 |
Mating flange associated with pipe run A |
|||
6 |
Component associated with pipe run A |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software does not delete the mating flange and generates a To Do Record for the mating flange. You must have Write access to the mating flange to update the To Do Record. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Working |
Read-only |
|
3 |
Base flange associated with pipe run A |
|||
4 |
Mating flanges associated with pipe run B |
|||
5 |
Mating reducer associated with pipe run B |
|||
6 |
Component associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including mating parts, all associated objects and connections. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Pipe run A |
Working |
Full control/ Write |
|
2 |
Pipe run B |
Non-working |
Full control/ Write |
|
3 |
Base flange associated with pipe run A |
|||
4 |
Mating flanges associated with pipe run B |
|||
5 |
Mating reducer associated with pipe run B |
|||
6 |
Component associated with pipe run B |
|||
Result: If you delete pipe run A, the software deletes pipe run A, including all associated objects and connections. The software generates a To Do Record for the mating flange. You must have Write access to the mating flange to update the To Do Record. |
||||
Before deletion |