  1. Select the SIO pipe runs to copy.

  2. Right-click the selected SIO pipe runs, and then select Copy SIO PipeRun to Smart 3D from the shortcut menu to open the CopySIOPipeRunToS3D Dialog.

  3. Select Generic Piping Components by Selected Spec to copy piping components without any mapping. Select a spec from the list. Alternatively, select Piping Parts by Mapping, and then navigate to the mapping file.

  4. Type a path and a log file name in the Log File box.

  5. Click Copy to start the command. The progress displays in the status bar. The software creates the Smart 3D pipe runs under the corresponding SIO pipeline, and appends _S3D to the selected SIO pipe run name. The software maintains the connectivity between the copied Smart 3D pipe runs.