If you are not familiar with importing and converting data to Smart Interop Objects, see the topic for your environment, listed below.

The Smart Interop Object Run End Rels are the relations between Smart Interop Object pipe runs. The Detect and Repair Missing Run End Relations custom command validates the Smart Interop Object runs, detects any missing Run End relations, and allows you to repair the ends of all the Smart Interop Object pipe runs.

Before you begin, make sure that the Detect and Repair Missing Run End Relations custom command is added to the software. The ProgID for this command is RouteDevCustomCmd,Ingr.SP3D.Route.Client.CustomCommand.SIORunsWithMissingRunEndRels. See Add custom commands in the Common Help.

  1. Open a design session and select the Smart Interop Object (SIO) pipe runs.

  2. Click Tools > Custom Commands, and run the Detect and Repair Missing Run End Relations custom command. If you did not select any SIO pipe runs before running the custom command, the Select Filter dialog displays allowing you to select or create the filter containing the desired runs.

  3. In the Report and Process SIO Runs with Missing RunEndRelations dialog, select the SIO piping run and click Process SIORunEnd Relations to repair the missing Run End relations between the pipe runs.

In the Report and Process SIO Runs with Missing RunEndRelations dialog, you can view the log and export the report to Excel.