When you export Smart 3D model data to PDMS, consider the key points listed below. For more information about recommended workflows regarding design and data exchange between Smart 3D and PDMS, including step-by-step examples, see Best Practices.

  • Follow the recommended naming conventions when modeling in Smart 3D:

    • Create a unique name for each modeled object so that no duplicates exist.

    • Make sure object names contain no spaces.

    • Make sure object names do not exceed 50 characters.

    • During export, if the software encounters a name that does not meet one of these conventions, it modifies the name before writing it to the DATAL file, resulting in mismatched object names between the two models.

    • If an object name in Smart 3D contains a space, the software replaces the space with an underscore (_) character in PDMS.

    • We recommend that you clear all To Do List messages before starting the export process.

  • Include first level objects when exporting Smart 3D model data to PDMS: Equipment, Pipeline, Duct Run, Cableway/Cable tray/Conduit run, Member systems/Root plate system, and Support assembly.

  • Export Smart 3D model data by discipline. Doing so reduces DATAL file size and assists in identifying and resolving export issues.

  • Export model data using the following sequence of supported object types: Equipment, Piping, HVAC, Electrical, Structure, Hangers and Supports.

  • Verify that the catalog component orientation in PDMS is correct before importing the DATAL file.

  • When exporting Smart 3D model data, you must create equivalent UDETs (User Defined Element Types) with relationships before importing the hierarchy DATAL file into PDMS. For more information, see Hierarchy Translation Maps.

  • Set Tolerance values (in the PDMS Piping Consistency Check options) to maximum before importing the DATAL files. Doing so helps resolve issues related to port misalignment and sloped piping.

  • Review the log file after each Smart 3D export for any errors or warnings.

  • Review the log file generated during model data import to PDMS for any errors or warnings.