Main Tab (Opening Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Molded Forms

Language
English
Product
Intergraph Smart 3D
Subproduct
Molded Forms
Search by Category
Help
Smart 3D Version
12.1 (2019)

Name

Specifies the name of the selected object. If the name is too long to entirely display in the box, point to the box to display the complete name as a tool tip. If the name is not defined by a rule, User Defined displays. If this name is generated by a naming rule, Naming Rule displays. If you type a name in this box, Smart 3D automatically changes the naming rule to User Defined.

Rule

Select the naming rule to use to name the opening.

  • Select StdHierarchyChildNamingRule to use the following syntax: <Parent Name>-<"Opening Entity"><Index Number>. For example, D0-1DCK-1-Opening Entity1, where D0 is the reference plane, 1DCK is an index number appended by the plate type (Deck in this example), 1 is the Workshare Location ID, and Opening Entity1 is Opening Entity appended by an index number.

  • Select User Defined if you want to name the opening yourself using the appropriate box.

Opening design type

Specifies the design opening property for the opening or hole. The default value is Permanent Access. The list is defined by the CutoutDesignType codelist.

Opening planning method

Specifies the planning opening property for the opening or hole. The default value is Design. The list is defined by the CutoutPlanningMethod codelist.

Opening production method

Specifies the production opening property for the opening or hole. The default value is Cut. The list is defined by the CutoutProductionMethod codelist.

For more information about opening properties, see Openings Command.