Use this procedure to reconnect all the objects from an old coordinate system to a new coordinate system.
-
Select Tools > Automatic Reconnect (Tools Menu) to display the Automatic Reconnect Dialog.
-
Click the Coordinate System Tab (Automatic Reconnect Dialog).
-
In the Old Coordinate System section, click Browse to select the coordinate system to which the objects are currently connected.
-
Select the Delete option to delete the old coordinate system after you reconnect.
-
The selected coordinate systems must be of type Cartesian Coordinate System.
-
-
In the New Coordinate System section, click Browse to select the coordinate system for the reconnection.
The software displays error messages for the following scenarios:
-
Selected coordinate systems are same.
-
Selected coordinate systems are of different types.
-
Selected coordinate systems are not identical in terms of geometry and topology.
-
-
After selecting both the old and new coordinate systems, the software compares the old and new coordinate systems before enabling the Reconnect.
-
Click Reconnect to reconnect all the objects from the old coordinate system to the new coordinate system.
The software displays the following error message if the reconnection fails.
-
Click View Log to see the reconnect status.
-
Click Close.