Controls the tolerance used when connecting components in IDFGEN.
Set a value in millimeters.
Defines:
Option Switch - 116, Pos 4-6
I-Configure - Drawing.Dimensions.IdfgenConnectionTolerance
To avoid problems when this property is set as a single value, no tolerance is set in Option Switch 116, Positions 4-6. IDFGEN continues to use positions 1-3 to determine the connection tolerance.