Process both simple and detailed physical aspects

In general, the detailed physical aspect geometry has a copy of simple physical aspect geometry as well as additional geometry. If the simple physical aspect geometry and detailed physical aspect geometry of a custom part are different, then you can customize the IFC rule to process both simple and detailed physical aspect geometries.

The IFC engine supports .NET IFC rule, Visual Basic 6.0 IFC rule, and Codeless IFC rule.

  • When you edit the IFC rule, use either the detailed physical aspect of the geometry, or the simple and detailed physical aspects of the geometry.

  • In the IFC rule, enable only the simple and detailed physical aspects interference checking for the required objects. Enabling the IFC with both aspects for all objects might slow down the clash detection.

  • The .NET IFC rule is the default IFC rule.

  • By default, the IFC rule considers the simple physical aspect geometry for pipe support, duct support, and cable tray support object types. For the remaining object types, the IFC rule considers the detailed physical aspect geometry.

  • Visual Basic 6.0 IFC rule is not delivered with Smart 3D. For information on Visual Basic 6.0 IFC rule, contact the Smart Community.