Replace Pipe Command - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Integration - Project As-Built with HxGN SDx

Language
English
Product
Intergraph Smart 3D
Subproduct
Project As-Built with SDx
Search by Category
Administration & Configuration
Smart 3D Version
13.1

The Replace pipe command replaces the selected straight or bent SIO pipe part with the equivalent native pipe.

If the software is not able to match the SIO pipe specifications with equivalent native pipe specifications, the Pipe replacement settings dialog displays. This might happen when you import third party data that has no equivalent pipe specifications in the software.

Limitations

  • If the replaced pipe has olet type branches or is a stub-in branch connected directly to a header pipe, the replaced pipe might get disconnected.

  • If surface mounted components or hangers are attached to a replaced pipe, you might need to check and repair any connectivity issues.

  • If you replace pipe parts with multiple bends, it might cause a skew in the pipe. To repair the skew, convert the entire pipe run to Smart 3D native pipe or remodel the entire pipe run.