Add Custom Schema Objects to the HxGN SDx2 Common Schema - Intergraph Smart 3D - Connectors & Integration - Hexagon

Intergraph Smart 3D Integration - HxGN SDx2

ft:locale
en-US
Product
Intergraph Smart 3D
Search by Category
Connectors & Integration
Smart 3D Version
14
Smart Interop Publisher Version
17
Platform
On-premises

You must map custom properties, interfaces, and classes to the HxGN SDx2 Common schema using HxGN Smart Admin. This involves creating a change request, relating the custom properties to the new change request, and then regenerating the common schema in HxGN SDx2.

Create a Change Request and Schema Objects Software Workflow

The charts below show the processes the software tools perform when you create a change request to extend or add custom properties, interfaces and classes to extend the Common HxGN SDx2 schema and update the Smart 3D tool schema.

Continued:

The steps below list the basic process. See Create Common Schema change request, Prepare Common Schema change request, and Regenerating the common schema for detailed workflow information.

Create a Change Request

  1. Launch HxGN Smart Admin and sign in using the appropriate credentials defined in your Authorization Server (SAM/OKTA).

  2. Select the Data Model Administration feature set.

  3. Select Create Common Schema Change Request.

  4. Add the details for the change request, and then select Finish.

Prepare Your Change Request

  1. In your To Do List, select Common Schema Change Request.

  2. Select the Prepare Common Schema CR workflow step, and then select Actions > Prepare Common Schema Change Request.

  3. Select options , and then select Manage Related Information.

  4. In Relationship Builder > Pins > New Items, select the schema objects required for the change request, and then select Relate.

    For example, relate the enum list types, enums, interface definitions, and property definitions.

  5. In Prepare Schema Change Request, select Complete.

Regenerate the Common Schema

Regenerate the common schema to ensure that an updated version of the common schema is used when authoring tools share or synchronize.

  1. Select Home Viz_Homeon the sidebar to return to the home page.

  2. Select the Data Model Administration feature set.

  3. Select Common Schema Change Requests to list all change request items in HxGN SDx2.

  4. Review all the schema objects related to the change request.

  5. From the Actions menu, select Regenerate Common Schema.

  6. When you receive the prompt, select Yes to regenerate the schema.

Next: Synchronize the SIOMap File and Common Schema